What is a hot deck cold deck system?

Hot deck/cold deck systems are an air handler based solution where the flow for the building is split into two, with one part being heated and one part being cooled. These two airflows are then mixed together to create the right amount of heating and cooling for each space.

What is hot deck temperature?

The hot deck set-point varies from 90°F to 70°F when the ambient temperature changes from 55°F to 70°F. When the ambient temperature is lower than 55″F, the hot deck set-point is 90°F.

What’s a hot deck?

: a pile of logs from which logs are hauled to the mill as soon as they are cut and yarded — compare cold deck.

How is a multi-zone air distribution system being controlled?

A thermostat controls each zone in the system. The multi-zone system is a variation of the dual-duct system. Multi-zone systems use zone dampers, located at the air unit, to mix heated air from a heating coil and chilled air from a chilled water coil to regulate the air temperature for a space, or zone.

What is a Texas multizone?

A “Texas Multizone” has a cooling coil in the cold deck and no coil in the bypass deck. Each zone has a separate heating coil. Before upgrade “Texas Multizones”, in general, supply a constant vol- ume of air to each zone. Room temperature is controlled at a room thermostat by varying supply air temperature.

What is multi zone VAV?

Multiple-zone VAV systems It is basically a calibrated air damper with an automatic actuator. The VAV terminal unit is connected to either a local or a central control system.

What is the purpose of the hot and cold decks on a multizone system?

What is the purpose of the hot and cold deck on a multi zone system? They provide simultaneous, hot and cold air. Can he and cool at the same time using a single air handler? By transferring heat between the ventilation, air and exhaust air.

How much does a 2 zone HVAC system cost?

HVAC Zoning System Cost

Number of Zones New Construction Existing Home
Two Zones $1,500 to $1,850 $2,000 to $2,500
Three Zones $1,850 to $2,100 $2,200 to $2,850
Four Zones $2,000 to $2,500 $2,650 to $3,300
Additional Zones $225 to $350 per zone $335 to $500 per zone

What is the difference between VAV and VRF?

VRF, variable refrigerant flow, is a more recent HVAC technology than VAV and uses refrigerant as its medium to heat and cool. A VRF system utilizes both indoor and outdoor components, with each outdoor unit (or the outdoor unit if only one is required) serving multiple indoor units.

What is VFD in HVAC?

A VFD is an electrical device used to control the rotation speed of an alternating current (AC) electric motor by adjusting the frequency of the electrical power supplied to the motor. Most VFDs used in HVAC applications are inverters using sine-coded PWM technology.

Can outside air ever be completely shut off from a space?

The amount of outside air required typically depends on the number of people occupying the space and the usage of the space 3. Can outside air ever be completely shut off from a space? Fire dampers close off the supply of outside air completely so that the fire is not fed any additional oxygen.

What are the different types of hot deck systems?

These two airflows are then mixed together to create the right amount of heating and cooling for each space. The main types of hot deck/cold deck system are: Multizone systems: For these systems, the hot air and cold air are mixed together in the plant room and the mixed air is ducted to each zone using dampers known as “face/bypass” dampers.

What should I do about my hot deck?

For hot deck/cold deck systems, the key opportunities are: Replacement/repair of face/bypass dampers to reduce leakage and possibly to provide independent hot/cold damper control (multizone systems). This can be achieved withut disturbance to tenants.

Where are the Ahus located in a HVAC system?

The systems were typically blow-through and usually consisted of both a cooling and heating coil, but placed in parallel and separated internally in the AHU. In Figure 5, there are two zones coming off the end of the AHU and would be considered a small AHU.